If you are seeing this message, then your Javascript is disabled. For better experience, kindly enable your Javascript.
Emmason
Integrated
Services
Search
Login
Sign Up
X
Home
Blog & News
Tutorial
Project Materials
Project Software
Seminar Materials
Bulk SMS
Scratch Cards
Name Dictionary
My Cart↓
View Cart
Verify Payment
History↓
Payment History
Download History
Settings↓
My Profile
Change Password
Delete Account
My Posts
Format:
Microsoft Word (.docx): Pages: 50+ pages: Chapters: 1-5
The full software or material containing all the chapters is available only when you make payment
Category: Project Material
INTERFACE MONITORING AND ANALYSIS OF PIPELINE AND PRODUCTS MARKETING COMPANY LIMITED ENUGU DEPOT
ABSTRACT/DESCRIPTION
This research was carried out with the sole aim of monitoring interface in the transportation of petroleum pipeline products and the analysis of this product from Enugu depot. In the research it was observed that product contaminates each other if interface was not properly monitored and cut at the appropriate time. The three major products that were considered in this research were premium motor spirit (PMS) automotive gas premium (AGO0 and dual purpose kerosene (DPK). The tests carried out point test smoke point test, initial and final boiling point test (Distillation), temperature and density test, to ascertain the standard quality specification and the extent of their purity. It was observed from the result that the flash point value for DPK and AGO were 430c and 820c respectively. The average smoke point test values for DPK product was 21.92mm. the initial and final boiling point of PMS were350c and 1750c, respectively. The observed density at the DPK/AGO interface monitoring test were 819 kg/m3 and 850 kg/m3 and corrected densities for DPK and AGO were 830.2kg/m3 and 859.9kg/m3 respectively. The interface reception cut point for DPK/AGO interface monitoring was made at the corrected density of 849.0 kg/m3. And the temperature of DPK and AGO were 310c respectively. The result from the analysis revealed that the boiling point of PMS was far more lower than that of AGI and DPK, which implies that PMS has a higher volatility than the two other products the flash point test revealed that the minimum temperature at which AGO and DPK ignites was 66.50c and 430c PMS was not determined because of its high volatility. Also, the standard minimum smoke point of DPK was determined to be 22mm. The smoke point test for AGO and PMS were not carried out because, they were not domestically used and their combustion normally takes value in an engine. This research has become very necessary because it reveals the proper way pf handling petroleum pipeline product to meet standard specification for domestic and industrial use
|
Other Topics From Your Department
1
THE ROLE OF PERSONNEL MANAGEMENT IN ENHANCING INDUSTRIAL HARMONY(A CASE STUDY OF COTTON MILLS ONITSHA)
2
THE IMPACT OF EMPLOYEE PARTICIPATION IN DECISION MAKING AND ORGANIZATIONAL PRODUCTIVITY(A CASE STUDY OF ANAMMCO ENUGU)
3
EFFECT OF ORGANIZATIONAL CHALLENGES FACING OWNERS OF SMALL AND MEDIUM SCALE ENTERPRISES IN A RECESSIVE BUSINESS ENVIRONMENT IN ENUGU METROPOLIS
4
THE PROBLEMS OF EXAMINATION MALPRACTICE IN HIGHER INSTITUTIONS AND HOW TO SOLVE THEM- A SPECIAL REFERENCE TO IMT ENUGU
5
THE INFLUENCE OF THE BUSINESS SUPPORT SYSTEM (AGENCIES) ON ENTREPRENEURIAL DEVELOPMENT(A CASE STUDY OF INDUSTRIAL DEVELOPMENT CENTRE (IDC) ASABA)
6
ADMINISTRATIVE STRESS AND MODERN MANAGER IN PRIVATE BUSINESS ORGANIZATION(A CASE STUDY HALLMARK BANK ENUGU)
7
APPLICATION OF TOTAL QUALITY MANAGEMENT TECHNIQUES THE MANUFACTURING SECTOR OF NIGERIA ECONOMY(A CASE STUDY OF EMENITE LTD EMENE ENUGU)
8
THE PLACE OF EMPLOYER AND EMPLOYEE RELATIONSHIP MANAGEMENT IN AN ORGANIZATION(A STUDY OF ECO – BANK, PLC, UGHELLI)
Emmason Integratded Services(2017-2026)
All Rights Reserved
Designed and Maintained By Emmason Integrated Services
.